Product Description
2500 Watt Power Inverter 12V 24V 48V Dc To Ac110V 220Vac 2500W Ture Sine Wave Inverter
Power inverter is a kind of products which change the DC electricity to AC electricity. It has been widely used in cars, steamboats, mobile offering post and telecommunications, public security, emergency and other field.
This power inverter has adopted the international lead circuit design, with the advantage of small size, light, stable, and high conversion efficiency. It has five kind of protect function such as: input under voltage protection, input over voltage protection, overload protection, over temperature protection, output short circuit protection.
Features:
Pure sine wave output ( THD < 3% )
Input & output completely isolated design
High efficiency93%
Loading and temperature controlled the cooling fan.
Protection: input low voltage alarm & shutdown, overload,short circuit, input over voltage, over temperature, reverse polarity
USB output port 5V2.1A
With Remote controller function /CR80 /CRD80 /CRD99 Remote controller with 5m cable optional,wireless remote controller optional.
LCD display function optional
2 years quality warranty, technical supporting whole life.
pure sine wave inverter specifications:
MODEL | FS2500D-112 | FS2500D-124 | FS2500D-148 | FS2500D-212 | FS2500D-224 | FS2500D-248 |
Output | AC Voltage | 100/110/120VAC | 220/230/240VAC |
Rated Power | 2500W |
Surge Power | Load 120~150%;5000W(3ms.;resistive) |
Waveform | Pure Sine Wave(THD<3%) |
USB port | 5V 2.1A | 5V 2.1A | ------ | 5V 2.1A | 5V 2.1A | ------ |
Frequency | 50/60Hz±0.05% |
AC Regulation | ±5% | ±10% |
Power Factor Allowed | COSθ-90º~COSθ+90º |
Standard Receptacles | USA/British/Franch/Schuko/UK/Australia/Universal etc.optional |
LED Indicator | Green for power on, red for faulty status |
LCD display | voltage, power, protection status(optional) |
Remote control function | default |
Remote controller | CR80/CRD80/CRW80 optional |
Input | No Load Current Draw | ≤1.2A | ≤0.80A | ≤0.70A | ≤1.2A | ≤0.80A | ≤0.70A |
DC Voltage | 12VDC | 24VDC | 48VDC | 12VDC | 24VDC | 48VDC |
Voltage Range | 10.5~15VDC | 21~30VDC | 42~60VDC | 10.5~15VDC | 21~30VDC | 42~60VDC |
Efficiency(Typ.) | 89%~93% |
Fuse | 40A×4 | 20A×4 | 10A×4 | 40A×4 | 20A×4 | 10A×4 |
Remote Control | Function(optional) |
Protection | BAT.Low Alarm | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC |
BAT.LOW Shutdown | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC |
Over Load | Shut down output voltage, restart to recover |
Over Voltage | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC |
Over Temperature | Shut down output voltage, recover automatically after temperature goes down |
Output Short | Shut down output voltage, restart to recover |
DC Input Reverse Polarity | By fuse |
Earth Fault | Shut off o/p when the load has electrical leakage |
Soft Start | Yes,3~5 Seconds |
Environment | Working Temp. | 0~+50℃ |
Working Humidity | 20~90%RH non-condending |
Storage Temp.&Humidity | -30~+70℃,10~95%RH |
Safety&EMC | Safty Standards | Certified UL 458(only for"GFCI"receptacles) | Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013. |
Isolation Resistance | I/P-O/P:100M Ohms/500VDC |
EMI Conduction&Radiation | Certified FCC class A | Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3; |
EMS Immunity | ------ | Certified IEC61000-4-3, IEC61000-4-6 |
E-MARK | ------ | Certified ECE RIO.05:2014 |
Others | Dimension(L×W×H) | 442.2*261.3*112.7mm |
Packing | 7.3kg;2pcs/15.5kg/0.07m³ |
Cooling | Load control fan or by thermal control fan |
Application | Home and Office appliances,Portable Power Equipment,Vehicle |
Product picures:






FAQ:
How to choose suitable inverter ?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave inverter. For example: fans, precision instruments, air conditioner, fridge,coffee machine, computer, and so on. Modified wave can be started with some inductive loads, but effect for load using life, because capacitive loads and inductive loads need highquality power.
............................................................................................................................................................
How do I choose the size of the inverter ?
Different types of load demand for power are different. You can view the load power values to determine the size of the inverter.
Notice: resistive load: you can choose the same power as the load. Capacitive loads: according to the load, you can choose 2-5 times power. Inductive loads: according to the load, you can choose 4-7 times power.
About solarway:
Jiaxing Solarway New Energy Company is a Sino-Germany Joint venture which is a professional off-grid power inverter manufacturer in Jiaxing city ,near to Shanghai,China . We are mainly engaged in high-tech DC TO AC inverter, DC TO DC converter, MPPT/PWM
sollar controller, solar panel and other solar system accessories, OEM and ODM service are available.All our products we have CE,RoHs,E-mark certification .We have R & D Center and After-sales Service Center in Beijing, China and Leipzig, Germany to make sure we have new design with patent every year.