Add to Cart
2000 watt pure sine wave power inverter with bypass function
Description:
Notice:
1. The 2000W inverter should be installed in a dry, well ventilated environment, keeping the inlet more than 20CM away from the wall.
2. DC input is not reversed, otherwise the fuse blows, possible mosfet failure.
3. Short-circuit fault, Restart after removing the fault, otherwise inverter damage.
4. Non-professional please don’t open the 2000W bypass inverter, because of the high voltage inside the inverter. When open by yourself without warranty.
pure sine wave inverter specifications:
| MODEL | TFS2000-112 | TFS2000-124 | TFS2000-148 | TFS2000-212 | TFS2000-224 | TFS2000-248 | |
| Output | AC Voltage | 100/110/120V AC | 220/230/240V AC | ||||
| Rated Power | 2000W | ||||||
| Surge Power | Load 120~150%(3min.); 3000W(3sec; resistive) | ||||||
| Waveform | Pure Sine Wave(THD<3%) | ||||||
| Frequency | 50/60Hz ±0.05% | ||||||
| AC Regulation | ±5% | ±10% | |||||
| Power Factor Allowed | COSθ-90°~COSθ+90° | ||||||
| Standard Receptacles | USA/British/Franch/Schuko /UK/Australia/Universal etc. optional | ||||||
| LED Indicator | Green for power on, red for faulty status | ||||||
| USB port | 5V 2.1A | 5V 2.1A | ------ | 5V 2.1A | 5V 2.1A | ------ | |
| LCD display | voltage, power, protection status ( optional) | ||||||
| Remote control function | default | ||||||
| Remote controller | CR80/CRD80 optional | ||||||
| Input | No Load Current Draw | ≤1.1A | ≤0.80A | ≤0.70A | ≤1.1A | ≤0.80A | ≤0.70A |
| DC Voltage | 12VDC | 24VDC | 48VDC | 12VDC | 24VDC | 48VDC | |
| Voltage Range | 10.5~15VDC | 21~30VDC | 42~60VDC | 10.5~15VDC | 21~30VDC | 42~60VDC | |
| Efficiency(Typ.) | 89%~93% | ||||||
| Fuse | 40A×6 | 20A×6 | 10A×6 | 40A×6 | 20A×6 | 10A×6 | |
| Remote Control | Function (optional) | ||||||
| Protection | BAT. Low Alarm | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC | 10.5±0.5VDC | 21±1.0VDC | 42±2.0VDC |
| BAT. Low Shutdown | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | 10±0.5VDC | 20±1.0VDC | 40±2.0VDC | |
| Over Load | Shut down output voltage , restart to recover | ||||||
| Over Voltage | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | 15.5±0.5VDC | 31±1.0VDC | 62±2.0VDC | |
| Over Temperature | Shut down output voltage , recover automatically after temperature goes down | ||||||
| Output Short | Shut down output voltage , restart to recover | ||||||
| DC Input Reverse Polarity | By fuse | ||||||
| Earth Fault | Shut off o/p when the load has electrical leakage | ||||||
| Soft Start | Yes, 3-5 Seconds | ||||||
| Environment | Working Temp. | 0~+50℃ | |||||
| Working Humidity | 20~90%RH non-condensing | ||||||
| Storage Temp.&Humidity | -30~+70℃,10~95%RH | ||||||
| Safety & EMC | Safety Standards | Certified UL 458(only for "GFCI" receptacles) | Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013. | ||||
| Isolation Resistance | I/P-O/P:100M Ohms/500VDC | ||||||
| EMI Conduction & Radiation | Certified FCC class A | Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3; | |||||
| EMS Immunity | ------ | Certified IEC61000-4-3, IEC61000-4-6 | |||||
| E-MARK | ------ | Certified ECE RIO.05:2014 | |||||
| Others | Dimension(L×W×H) | 325.2×281.3×112.7mm | |||||
| Packing | 5.2kg;2pcs/11.1kg/0.053m³ | ||||||
| Cooling | Load control fan or by thermal control fan | ||||||
| Application | Home and Office appliances,Portable Power Equipment,Vehicle,Yacht and Off-Gid Solar power systems…etc. | ||||||
Product picures:



About solarway:
Jiaxing Solarway New Energy Company is a Sino-Germany Joint venture which is a professional off-grid power inverter manufacturer in Jiaxing city ,near to Shanghai,China . We are mainly engaged in high-tech DC TO AC inverter, DC TO DC converter, MPPT/PWM
sollar controller, solar panel and other solar system accessories, OEM and ODM service are available.All our products we have CE,RoHs,E-mark,ETL certification .We have R & D Center and After-sales Service Center in Beijing, China and Leipzig, Germany to make sure we have new design with patent every year.